Three Phase Hybrid Storage Inverter 7-12 KW (LV Battery Supported)
AF7K-12K-TL
The Afore AF low voltage series storage Inverters are designed to increase energy independence for homeowners. The power range is from 7kW to 12kW, compatible with low voltage (40-60V) batteries.
Energy management is based on time-of-use and demand charge rate structures, which significantly reduce the amount of energy purchased from the public grid.
Thanks for the UPS function (switch time < 10ms), that enables the crucial loads power on during outages. Additionally, under the backup operation mode, the inverter provides you up to 150% peak output overloading.
The Afore energy storage inverter features Smart Electricity Pricing & Automation, an energy management tool based on real-time electricity pricing strategies. It continuously monitors electricity price fluctuations and dynamically adjusts device operation accordingly. Operating 24/7 fully automatically without the need for manual intervention, it helps users optimize their electricity usage and reduce energy costs.
Product introduction

AI EMS
Electricity Pricing
& Automation

MAX. 370A
Max. Charge/
Discharge Current 370A

100% UNBALANCE
Support unbalance load

MPPT CHANNELS
Up to 2 MPPT Channels

UPS FUNCTION
Switch Time < 10ms

PARALLEL
Max.6 Parallel Stacking

INPUT
Support Generator
Technical Data | AF7K-TL | AF8K-TL | AF9K-TL | AF10K-TL | AF11K-TL | AF12K-TL |
---|---|---|---|---|---|---|
PV Input | ||||||
Max.Input Power (kW) | 10.5 | 12 | 13.5 | 15 | 16.5 | 18 |
Max. PV Voltage (V) | 950 | 950 | 950 | 950 | 950 | 950 |
MPPT Range (V) | 80-900 | 80-900 | 80-900 | 80-900 | 80-900 | 80-900 |
Ful MPPT Range (V) | 180-850 | 200-850 | 225-850 | 250-850 | 275-850 | 300-850 |
Normal Voltage (V) | 650 | 650 | 650 | 650 | 650 | 650 |
Startup Voltage (V) | 100 | 100 | 100 | 100 | 100 | 100 |
Max. Input Current (A) | 26+18.5 | 26+18.5 | 26+18.5 | 26+18.5 | 26+18.5 | 26+18.5 |
Max. Short Current (A) | 32+25 | 32+25 | 32+25 | 32+25 | 32+25 | 32+25 |
No.of MPP Tracker / No. of PV String | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 |
Battery Port | ||||||
Max. Charge/Discharge Power (KW) | 10.5 | 12 | 13.5 | 15 | 16.5 | 18 |
Max. Charge/Discharge Current (A) | 220 | 250 | 280 | 310 | 340 | 370 |
Normal Charge/Discharge Current(A) | 180 | 200 | 230 | 250 | 275 | 300 |
Battery Normal Voltage (V) | 51.2 | 51.2 | 51.2 | 51.2 | 51.2 | 51.2 |
Battery Voltage Range (V) | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 |
Battery Type | Li-ion/Lead-acid etc. | Li-ion/Lead-acid etc. | Li-ion/Lead-acid etc. | Li-ion/Lead-acid etc. | Li-ion/Lead-acid etc. | Li-ion/Lead-acid etc. |
AC Grid | ||||||
Max Continuous Current (A) | 11 | 12 | 14 | 15 | 17 | 18 |
Max Continuous Power (KVA) | 7 | 8 | 9 | 10 | 11 | 12 |
Nominal Grid Current (A) | 11/10.5 | 11/10.5 | 11/10.5 | 11/10.5 | 11/10.5 | 11/10.5 |
Nominal Grid Voltage (V) | 380/400 | 380/400 | 380/400 | 380/400 | 380/400 | 380/400 |
Nominal Grid Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Power Factor | 1 default (adjustable from 0.8 leading to 0.8 lagging) | 1 default (adjustable from 0.8 leading to 0.8 lagging) | 1 default (adjustable from 0.8 leading to 0.8 lagging) | 1 default (adjustable from 0.8 leading to 0.8 lagging) | 1 default (adjustable from 0.8 leading to 0.8 lagging) | 1 default (adjustable from 0.8 leading to 0.8 lagging) |
Current THD(%) | <3 | <3 | <3 | <3 | <3 | <3 |
AC Load Output | ||||||
Max Continuous Current (A) | 11 | 12 | 14 | 15 | 17 | 18 |
Max Continuous Power (KVA) | 7 | 8 | 9 | 10 | 11 | 12 |
Max Peak Current (A) (60s) | 22/21 | 24/23 | 28/26 | 30/29 | 34/32 | 36/35 |
Max Peak Power (kVA) (60s) | 10.5 | 10.5 | 10.5 | 10.5 | 10.5 | 10.5 |
Nominal AC Voltage L-N (V) | 380/400 | 380/400 | 380/400 | 380/400 | 380/400 | 380/400 |
Nominal AC Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Switching Time (ms) | Seamless | Seamless | Seamless | Seamless | Seamless | Seamless |
Voltage THD (%) | <3 | <3 | <3 | <3 | <3 | <3 |
Efficiency | ||||||
CEC Efficiency(%) | 96.8 | 96.8 | 96.8 | 96.8 | 96.8 | 96.8 |
Max. Efficiency (%) | 98.1 | 98.1 | 98.1 | 98.1 | 98.1 | 98.1 |
Protection | ||||||
PV Reverse Polarity Protection | Yes | Yes | Yes | Yes | Yes | Yes |
Bat. Reverse Polarity Protection | Yes | Yes | Yes | Yes | Yes | Yes |
Over Current/Voltage Protection | Yes | Yes | Yes | Yes | Yes | Yes |
Anti-Islanding Protection | Yes | Yes | Yes | Yes | Yes | Yes |
AC Short Circuit Protection | Yes | Yes | Yes | Yes | Yes | Yes |
Residual Current Detection | Yes | Yes | Yes | Yes | Yes | Yes |
Ground Fault Monitoring | Yes | Yes | Yes | Yes | Yes | Yes |
PV Arc Detection | Yes | Yes | Yes | Yes | Yes | Yes |
Enclosure Protect Level | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
AC/DC surge protection | Type II | Type II | Type II | Type II | Type II | Type II |
General Data | ||||||
Dimensions (W x H x D,mm) | 600x400x250 | 600x400x250 | 600x400x250 | 600x400x250 | 600x400x250 | 600x400x250 |
Weight(kg) | 30 | 30 | 30 | 30 | 30 | 30 |
Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless |
Cooling | Intelligent Fan | Intelligent Fan | Intelligent Fan | Intelligent Fan | Intelligent Fan | Intelligent Fan |
Relative Humidity | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
Operating Altitude (m) | <3000 | <3000 | <3000 | <3000 | <3000 | <3000 |
Standby Consumption (W) | <10 | <10 | <10 | <10 | <10 | <10 |
Mounting | Wall Bracket | Wall Bracket | Wall Bracket | Wall Bracket | Wall Bracket | Wall Bracket |
Communication with RSD | SUNSPEC | SUNSPEC | SUNSPEC | SUNSPEC | SUNSPEC | SUNSPEC |
Display & Communication Interfaces | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G, Sunspec | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G, Sunspec | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G, Sunspec | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G, Sunspec | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G, Sunspec | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G, Sunspec |